Malvern Panalytical / Empyrean MultiCore High-Performance X-ray Diffractometer

Multi-purpose X-ray Facility

High-resolution, high-power X-ray diffractometer for analysis of thin film or polycrystalline materials

Enquire Now

Or call us now on 0161 275 8382

Detailed Description

The Malvern Panalytical Empyrean with MultiCore Optics offers the latest in high-quality analysis of challenging samples by X-ray methods (diffraction or reflectometry, including grazing incidence, texture, stress, 2D diffraction etc.). Sample stages for receiving both thin films and polycrystalline powders are available, including auto-changers and a 5-axis cradle. The MultiCore optics means the configuration can be changed without physical intervention, and multiple experiments using different techniques can be programmed together. Mapping and variable-temperature studies (Anton Paar DCS 500 Domed cooling stage,  93 K < T < 773 K) can be carried out on all samples.
High-resolution data with superior sensitivity are collected using a combination of the 4 kW Cu X-ray tube, PIXcel3D detector and advanced optics, including 2 and 3 bounce hybrid monochromators. Thin film samples up to 80mm in diameter can be mounted on the 5-axis cradle, with those up to 140mm mounted on a three-axis stage. Powders can be received on flat plates (transmission or reflection), or in capillaries. A full suite of analysis software is available, and support in advanced analysis and calibrated instrument parameter files are available.

Uses/Applications

Suitable for analysis of advanced materials, in particular thin films (10 – 100 nm) and epitaxial thin films for devices, as well as poly- and nanocrystalline samples and solid foils:
• High-resolution 1D X-Ray diffraction, 2D X-Ray diffraction, transmission XRD, and grazing incidence X-ray diffraction (GIXRD) available.
• X-Ray reflectometry (XRR) on thin-film samples, including multi-layer and ultra-thin films.
• Reciprocal space map (RSM), rocking curve, residual stress, pole figure measurements possible, including fast scans.
• Variable-temperature  measurements to test stability, cycling performance etc.
• ‘Click to measure’ mapping capability of thin film samples.

Note, in using this instrument you must confirm that the PIXcel3D detector, and the CERN Medipix 2 and/or Medipix 3 chip technology therein, is only used for X-ray analysis purposes. Please contact us for further details on samples we may not be able to accept (in particular, medical, military, nuclear or space applications).

• 4 kW Cu X-ray source (60 kV/100 mA).
• PIXcel3D detector.
• Flat plate and capillary powder sample holders.
• 3-axis (for thin film samples up to 140 mm in diameter) and 5-axis cradle (for samples up to 80 mm diameter).
• Variable-temperature capability for powders and thin films (93 K – 773 K).
• Standard optics for a variety of techniques easily switchable using MultiCore optics (FWHM ≤ 0.007º (≤ 26”), powder diffraction FWHM as low as 0.026º 2Θ).
• High-resolution beam path using both incident and diffracted beam monochromator available (acceptance of 0.0033º in diffracted beam path).